Automation Redefined for IHC, ISH & FISH
Learn More >
Pro Performance For Your Laboratory
A New Standard in Automated Staining Technology
Fully Automated IHC/ISH/FISH Staining
Biocare Optimized Reagents or Third Party Reagents
Ease of Use / User Interface
Dispense Volume – 25 uL minimum – 5 mL maximum
QR Code Scanning Technology
Hazardous Waste Separation
For Even The Most Demanding Laboratories
The NeoPATH Pro simplifies high-volume laboratory workflows by integrating advanced features – including a 42-slide and 56-reagent capacity, continuous and random access capabilities, and real-time data tracking – into one powerful platform for IHC, ISH, and FISH. Developed with firsthand lab insights, it delivers exceptionally clear, crisp staining while maximizing throughput. Whether placed on a bench or freestanding, the NeoPATH Pro helps your team work smarter, and faster – setting a new standard in automated staining technology.
Automation Designed For All Labs
Neopath pro specifications
Applications |
IHC, ISH, FISH |
Slide Capacity |
42 Slides |
Reagent Rack |
7 Reagent Racks, each consists of 8 Vials (Total 56 vials) |
Bulk Reagents |
6 Bulk Containers (Max volume: 2000 mL each) |
Carboys & Waste separation |
Wash Buffer (25 L), Cleaning Solution (25 L) |
Antigen Retrieval Temperature Range |
25°C to Max 115°C at Sea Level |
Reagent Capacity |
2.5 mL, 15 mL, 50 mL |
Syringe Capacity |
5 mL |
Dispense Volume |
25 uL minimum – 5 mL maximum |
Unit Control |
One Instrument Per Computer |
Instrument Weight |
330.70 lbs (150 kg) |
Instrument Weight (with Dock Accessory) |
573.20 lbs (260 kg) |
Instrument Dimensions |
(Door Closed – W x H x D) 54.33 in x 31.49 in x 29.52 in / 138 cm x 80 cm x 75 cm |
Instrument Dimensions (with Dock Accessory) |
(Door Closed – W x H x D) 55.16 in x 64.25 in x 29.53 in / 140.20 cm x 163.20 cm x 75 cm (Door Open – W x H x D) 55.16 in x 82.70 in x 29.53 in / 140.20 cm x 210 cm x 75 cm (Setup space with PC) W 78.78 in / W 200.20 cm |
Electrical Requirements |
Voltage : 100 – 240 VAC Frequency: 50 – 60 Hz |
UPS Requirements |
120VAC UPS: Power Capacity (VA): 1500 VA – Voltage Required: AC 100/110/120 V |
Noise Rating |
60 dBA at 1.5 Meter Distance |
Reports |
Slide QR Code, Patient Information, Staining Runs |
LIS |
HL7 Server Connection |
Reagent Rack Temperature |
18 – 22°C |
Programmable Delayed Start |
Up to 48 hours |
Operating Conditions |
5 – 32°C |
Operating Process |
Continuous, Random Loading & Unloading |
Antibodies |
Pre-optimized, Ready-to-use antibodies. Open reagent containers available for antibodies |